Hoymiles · HIT Series · Three-phase

Hoymiles HIT Series Hybrid Inverters

6 to 20 kW · 5 models in the B2B shop · Battery 40 to 60 V

Three-phase hybrid inverters for low-voltage batteries, from the 6 kW class with color display to the flagship HIT-20L-G3: 22,000 VA on-grid, up to 40 kW PV on four MPP trackers and up to 350 A charge and discharge current. In on-grid mode, the bypass carries up to 50 A to the backup loads. If the grid fails, the unit keeps supplying these loads on all three phases, briefly at twice the rated power, provided PV and battery can deliver it.

  • Up to 4 MPPT at 20 A each
  • Three-phase backup power, 50 A bypass
  • Up to 16 LB-G3 battery modules
  • Inverter rated IP66
Hoymiles hybrid inverter HIT-20L-G3 with LED ring next to the low-voltage battery LB-16D-G3, shown true to scale
HIT-20L-G3 (539 × 696 × 232 mm) with LB-16D-G3 (16.08 kWh)

In brief

What the Hoymiles
HIT Series is

The Hoymiles HIT Series is a range of three-phase hybrid inverters for low-voltage batteries in the voltage range from 40 to 60 V. One unit connects the PV array, battery, grid and, if required, a generator, and keeps supplying the connected loads on all three phases during a grid outage.

Hoymiles manufactures the range in eight power classes from 5 to 20 kW, each with LED ring (G3) or color display (G3S). PVSelected stocks five models in its B2B shop: HIT-6L-G3S and HIT-8L-G3S with color display as well as HIT-10L-G3, HIT-15L-G3 and HIT-20L-G3 with LED ring. They are complemented by the batteries LB-6D-G3 (6.02 kWh), LB-16D-G3 (16.08 kWh) and the stackable battery LB-5S-G2 (5.12 kWh).

PVSelected supplies the range to installers in Germany, Austria, Switzerland and the Netherlands. Warehouse: Halskestraße 3-5, 47877 Willich.

Device type
Hybrid inverterthree-phase, 3L/N/PE, 380/400 V, for batteries with 40 to 60 V
Power classes
6 to 20 kWfive models in the B2B shop, manufacturer range 5 to 20 kW
PV input
12 to 40 kWrecommended max. PV power, 2 to 4 MPPT at 20 A each, 150 to 900 V
Battery
LB-G3 and LB-S-G2LB-G3: LiFePO4, 51.2 V, up to 16 modules in parallel
Backup power
2 × rated powerfor 10 s, provided PV and battery can deliver it; 50 A bypass in on-grid mode; switchover 10 ms max.
Protection rating
IP66inverter, -25 to +65 °C; LB-G3 battery IP65 with self-heating

Why this range

Six reasons that
count on site

Several roof areas on one unit, backup power for the entire distribution board, reserve for starting currents and a unit that can be mounted outdoors. Six arguments to help you sell the HIT.

01 · PV input

Several roof areas, one unit

The larger classes have four MPP trackers, each with 20 A input current and 30 A short-circuit current. Each roof area gets its own tracker and is optimized separately: shading or a different orientation on one area does not affect the output of the other trackers. DC/AC oversizing of up to 200 % is permitted.

MPP trackers per class: HIT-6L-G3S 2, HIT-8L-G3S 3, HIT-10L-G3 3*, HIT-15L-G3 and HIT-20L-G3 4 each. MPP voltage range 150 to 900 V, start-up from 150 V. According to the manufacturer, the low start-up voltage adds about half an hour of generation time.

20 AInput current per MPP tracker

Hoymiles HIT inverter with LED ring, house seen from above with four differently oriented PV roof areas connected separately to the inverter
Four roof areas on four MPP trackers, as with HIT-15L-G3 and HIT-20L-G3
02 · Backup power

Backup power for the entire distribution board

In on-grid mode, the backup loads run through the integrated bypass with up to 50 A continuous current. If the grid fails, the HIT disconnects from the grid and keeps supplying the loads on the EPS output on all three phases, including the entire house distribution board if it is connected there. In backup mode, 100 % unbalanced load is permitted, up to 50 % of the rated power per phase, so single-phase loads keep running as well.

According to the G3 datasheet, the switchover time is below 10 ms. The manufacturer's documents state different values, so we plan for 10 ms max.

50 ABypass continuous current in on-grid mode

Illuminated single-family home at night during a thunderstorm, the house remains supplied during a grid outage
Backup mode: the house stays supplied during a grid outage
03 · Starting reserve

Reserve for heat pumps and motors

In backup mode, the HIT provides twice its rated power for ten seconds, up to 40,000 VA with the HIT-20L-G3, provided PV and battery supply enough power. This reserve is intended for the starting currents of heat pumps, pumps or compressors. Whether it is sufficient depends on the starting current of the load and on the battery: an LB-16D-G3 delivers up to 240 A for 10 seconds, an LB-6D-G3 up to 90 A.

Without PV, at night for example, the battery limits the peak. Calculated value: one LB-16D-G3 alone 240 A × 51.2 V, approx. 12.3 kW for 10 s; the HIT-20L-G3's battery limit of 350 A corresponds to approx. 17.9 kW. The system brochure also states twice the power for 10 s in off-grid operation.

2 ×rated power for 10 seconds, depending on PV and battery

Hoymiles LB-G3 battery with indicated self-heating against a split background of ice and thunderstorm rain
LB-G3 battery with self-heating: it contributes to the starting peak, the LB-16D-G3 with up to 240 A for 10 s
04 · Energy sources

PV, battery, grid and generator

The HIT manages four energy sources: PV, battery, grid and generator. Instead of a generator, the GEN port can also supply loads and control their power consumption. The energy management integrates generator, heat pump and controllable loads, and up to ten inverters can operate in parallel, both on-grid and off-grid.

Interfaces according to the Quick Installation Guide: heat pump via analog signal or SG Ready, charging station and external control via RS485, external emergency stop.

4Energy sources on one unit

Hoymiles HIT inverter with LED ring on a facade, below it two stacked batteries of the G2 generation, on the left a hot water tank with immersion heater, on the right the PV connection
Manufacturer example: HIT-G3 with G2 stackable battery and immersion heater in the hot water tank
05 · Tariffs

Charge when power is cheap

In addition to self-consumption and peak shaving, the HIT handles time-of-use tariffs: up to eight schedules of 24 hours each define when the battery charges and when it supplies the house. With tariffs that have fixed time windows, the battery charges during low-cost hours and supplies the house during expensive ones.

Hoymiles states up to 8 % higher revenue through tariff control, a manufacturer's figure with no test conditions stated.

8 %higher revenue according to the manufacturer

Time-of-use tariffs: charging at low, discharging at high electricity pricesSchematic illustration of the time-of-use operating mode of the Hoymiles HIT inverter. The battery charges when the electricity price is low and discharges when it is high. No prices shown.Electricity priceTimeChargingat low priceDischargingat high priceTime-of-use tariffs: charging at low, discharging at high electricity pricesSchematic illustration of the time-of-use operating mode: the battery charges when the electricity price is low and discharges when it is high. No prices shown.Electricity priceTimeChargingLow priceDischargingHigh price
  • Battery charges
  • Battery supplies the house
Schematic illustration, no prices shown
06 · Outdoor installation

Can be mounted on an outside wall

The inverter is rated IP66 and operates from -25 to +65 °C, with derating from 45 °C. The Quick Installation Guide permits outdoor wall mounting exposed to sun, rain and snow. The LB-G3 batteries can be installed indoors or outdoors, rated IP65, with self-heating for -20 to 55 °C.

According to the manufacturer, the LB-S-G2 stackable battery is rated IP66 and operates from -10 to 45 °C.

IP66Inverter, outdoor installation

Hoymiles HIT inverter with LED ring on a light-colored outside wall next to a window
HIT-G3 inverter on an outside wall

Installation examples

What the HIT looks
like on site

Manufacturer images from homes, garages and plant rooms. For the batteries, the images show both generations; each caption states which one.

Hoymiles HIT inverter with LED ring on a garage wall, below it a G2 battery stack of PDU box, one battery pack and base
HIT-G3 with LED ring, below it a G2 stack of PDU box, pack and base
Hoymiles HIT inverter on the garage wall next to two G2 battery stacks, the cable leads to the house distribution board and on to the loads in the living area
HIT-G3 with two G2 battery stacks, cable to the house distribution board
Hoymiles LB-G3 batteries in three installation types: on wheels, on the wall and on the floor of a garage
LB-G3 batteries on wheels, on the wall and on the floor
Hoymiles HIT inverter with LED ring on a wooden wall, below it a stackable battery of the G2 generation
HIT-G3 with stackable battery of the G2 generation on a wooden wall
Hoymiles HIT inverter with LED ring, two flat battery modules of the G2 generation and a Hoymiles wallbox on a gray wall
HIT-G3, two G2 battery modules and Hoymiles wallbox
Hoymiles HIT-G3S with color display, low-voltage battery LB-G3 and Hoymiles wallbox as a product family
HIT-G3S with color display, LB-G3 battery and wallbox
Manufacturer example: single-family home with PV system, Hoymiles HIT inverter, two G2 battery stacks, generator, wallbox and electric car in the garage, and the house distribution board

The complete system

One system for roof,
battery, house and car

PV array, battery, backup loads and charging point are connected to one inverter and come together in one interface. Which functions are ultimately available is decided when you order.

Model overview

Five models,
two display variants

Housing, dimensions and weight are the same for all five: 539 × 696 × 232 mm and 41 kg. The smaller classes have a color display, the larger ones an LED ring. We carry all five models in our B2B shop.

Hoymiles hybrid inverter HIT-6L-G3S with color display, front view
Color display

HIT-6L-G3S

Rated power
6,000 W
Max. AC output
6,600 VA
Rec. max. PV
12,000 W
MPP trackers
2
Battery current
150 A
Backup 10 s ¹
12,000 VA
Max. efficiency
98.2 %
Hoymiles hybrid inverter HIT-8L-G3S with color display, angled view from the right
Color display

HIT-8L-G3S

Rated power
8,000 W
Max. AC output
8,800 VA
Rec. max. PV
16,000 W
MPP trackers
3
Battery current
190 A
Backup 10 s ¹
16,000 VA
Max. efficiency
98.2 %
In the shop: coming soon
Hoymiles hybrid inverter HIT-10L-G3 with LED ring, front view
LED ring

HIT-10L-G3

Rated power
10,000 W
Max. AC output
11,000 VA
Rec. max. PV
20,000 W
MPP trackers
3*
Battery current
210 A
Backup 10 s ¹
20,000 VA
Max. efficiency
98.2 %
Hoymiles hybrid inverter HIT-15L-G3 with LED ring, angled view from the right
LED ring

HIT-15L-G3

Rated power
15,000 W
Max. AC output
16,500 VA
Rec. max. PV
30,000 W
MPP trackers
4
Battery current
300 A
Backup 10 s ¹
30,000 VA
Max. efficiency
98.5 %
Hoymiles hybrid inverter HIT-20L-G3 with LED ring, underside with connection panel
LED ring

HIT-20L-G3

Rated power
20,000 W
Max. AC output
22,000 VA
Rec. max. PV
40,000 W
MPP trackers
4
Battery current
350 A
Backup 10 s ¹
40,000 VA
Max. efficiency
98.5 %
The five shop models compared
ModelDisplayRated powerMax. apparent powerRec. max. PVMPPTBattery currentBackup 10 s ¹Max. / EU efficiencyItem no.
HIT-6L-G3SColor display6,000 W6,600 VA12,000 W2150 A12,000 VA98.2 / 97.6 %C180500032
HIT-8L-G3SColor display8,000 W8,800 VA16,000 W3190 A16,000 VA98.2 / 97.6 %C180500033
HIT-10L-G3LED ring10,000 W11,000 VA20,000 W3*210 A20,000 VA98.2 / 97.6 %CV030100
HIT-15L-G3LED ring15,000 W16,500 VA30,000 W4300 A30,000 VA98.5 / 98.0 %CV030107
HIT-20L-G3LED ring20,000 W22,000 VA40,000 W4350 A40,000 VA98.5 / 98.0 %CV030099

* HIT-10L-G3: the shop designation and the datasheet of the G3S series state 3 MPP trackers for the 10 kW class, the G3 REV1.0 datasheet states 4. We plan for 3.

¹ Backup 10 s: peak of the inverter, only achievable if PV and battery supply enough power. From the battery alone, the battery current is the limit, calculated at approx. 12.3 kW with one LB-16D-G3 (240 A × 51.2 V) or 4.6 kW with one LB-6D-G3 (90 A × 51.2 V).

HIT-8L-G3S is marked as coming soon in the shop. Values from the manufacturer's datasheets G3 REV1.0 (© 2024) and G3S REV1.2 (© 2026).

Ready-made packages in the B2B shop

Inverter, battery,
meter and data stick

Five matched packages, each with Smart Meter and data stick (Data Transfer Stick). Prices and availability are shown after logging in to the shop.

Hoymiles HIT-6L-G3S with color display next to the LB-6D-G3 battery
Battery G3

6 kW with 6.02 kWh

HIT-6L-G3S, 1 × LB-6D-G3, Smart Meter and data stick

Hoymiles HIT-8L-G3S with color display next to the LB-6D-G3 battery
Battery G3

8 kW with 6.02 kWh

HIT-8L-G3S, 1 × LB-6D-G3, Smart Meter and data stick

Contains HIT-8L-G3S, marked as coming soon in the shop
Hoymiles HIT-15L-G3 with LED ring next to the LB-16D-G3 battery
Battery G3

15 kW with 16.08 kWh

HIT-15L-G3, 1 × LB-16D-G3, Smart Meter and data stick

Hoymiles HIT-20L-G3 with LED ring next to the LB-16D-G3 battery
Battery G3

20 kW with 16.08 kWh

HIT-20L-G3, 1 × LB-16D-G3, Smart Meter and data stick

Hoymiles HIT-6L-G3S with color display next to the G2 stackable battery consisting of PDU box, pack and base
Battery G2

6 kW with 5.12 kWh

HIT-6L-G3S, 1 × LB-5S-G2-Pack with base and PDU box LB-10C-G2, Smart Meter and data stick

Package contents as per the shop title and item list. The 6 kW package with 5.12 kWh uses the stackable battery of the G2 generation, the others the LB-G3 battery. Also in the shop: the extended warranty service EWS-5Y (5 additional years) for HIT-10L-G3 and HIT-15/20L-G3. EWS-5Y for HIT-10L-G3 · EWS-5Y for HIT-15/20L-G3

Sizing

True to
scale

The images are shown at the same scale. The inverter measures 539 × 696 × 232 mm. The LB-G3 batteries are individual units for wall, floor or wheeled installation and are connected electrically in parallel, up to 16 modules per system.

Hybrid inverter Hoymiles HIT-6L-G3S with color display, front view for size comparison
HIT-6L/8L-G3SH 696 mm · 41 kg
Low-voltage battery Hoymiles LB-6D-G3 (6.02 kWh), front view for size comparison
LB-6D-G36.02 kWh · H 514 mm · 55 kg

6 and 8 kW classes with color display

As in the 6 or 8 kW shop package with 6.02 kWh

Hybrid inverter Hoymiles HIT-20L-G3 with LED ring, front view for size comparison
HIT-10L/15L/20L-G3H 696 mm · 41 kg
Low-voltage battery Hoymiles LB-16D-G3 (16.08 kWh), front view for size comparison
LB-16D-G316.08 kWh · H 824 mm · 115 kg

10 to 20 kW classes with LED ring

As in the 15 or 20 kW shop package with 16.08 kWh

Example: a HIT-20L-G3 with two LB-16D-G3 gives 32.16 kWh (calculated value). Fully expanded with 16 modules, the calculated capacity is 96.32 kWh with LB-6D-G3 and 257.28 kWh with LB-16D-G3. The stackable battery LB-5S-G2 (5.12 kWh per pack) stands on its own base; according to the manufacturer, the LB-(5-20)S-G2 range covers 5.12 to 102.4 kWh.

Sizing calculator

A suggestion in
ten seconds

Enter the PV power and the desired battery capacity, then choose the battery type. The calculator suggests the matching power class, the number of modules, the possible battery current and, where it fits, the ready-made package from the B2B shop.

28.0kWp
3 kWp80 kWp
16kWh
5 kWh257 kWh

The calculator selects the smallest class in the shop whose recommended maximum PV power according to the datasheet covers the module power entered (12, 16, 20, 30 or 40 kW). The battery current is the minimum of the inverter limit and the sum of the continuous module currents; the backup peak from the battery is the minimum of the battery limit and the sum of the 10 s module currents, each multiplied by 51.2 V, as a calculated value. The calculator does not replace planning: orientation, load profile and the grid operator's requirements are not taken into account. That is exactly what the request is for.

Suggestion

HIT-15L-G3LED ring · 4 MPPT · rec. max. PV 30,000 W · 15 kW AC

1×Number of battery modules
16.08kWhBattery capacity
160ABattery current, calculated
156kgTotal weight

    The calculator selects the smallest class in the shop whose recommended maximum PV power according to the datasheet covers the module power entered (12, 16, 20, 30 or 40 kW). The battery current is the minimum of the inverter limit and the sum of the continuous module currents; the backup peak from the battery is the minimum of the battery limit and the sum of the 10 s module currents, each multiplied by 51.2 V, as a calculated value. The calculator does not replace planning: orientation, load profile and the grid operator's requirements are not taken into account. That is exactly what the request is for.

    System configuration

    What goes on the order
    with the HIT

    The inverter alone does not make a storage system. These components determine which functions are available.

    Hoymiles HIT-G3S with color display and HIT-G3 with LED ring side by side, same housing
    Required

    HIT hybrid inverter

    Five classes from 6 to 20 kW in the shop. Smaller classes with color display, larger ones with LED ring.

    Low-voltage battery Hoymiles LB-16D-G3 with self-heating, front view
    For backup power and self-consumption

    Battery LB-G3 or LB-S-G2

    LB-6D-G3 and LB-16D-G3 in parallel, up to 16 modules; or the stackable battery LB-5S-G2 with base and PDU box.

    Smart Meter and Data Transfer Stick (WLAN data logger) from the Hoymiles HIT system package
    For control and monitoring

    Smart Meter and data stick

    Meter with three current transformers at the grid connection point and data stick for the S-Miles Cloud. Included with the G3 models and part of the shop packages.

    Hoymiles AC wallbox with Type 2 charging cable, front view
    Optional

    Hoymiles AC wallbox

    Part of the system according to the manufacturer, connected to the HIT via RS485. Currently not available in the B2B shop. More on charging solutions on our page Hoymiles EV Charger.

    How everything fits together

    System diagram of the Hoymiles HIT Series: PV array, hybrid inverter, batteries LB-6D-G3 and LB-16D-G3, main loads, backup loads, generator, Smart Meter, grid, AC wallbox, data stick and S-Miles Cloud
    • DC sidePV array and LB-G3 battery are connected directly to the inverter.
    • AC sideMain loads and grid via the Smart Meter, backup loads on the EPS output, generator on the GEN port, plus the AC wallbox.
    • CommunicationBattery via CAN, Smart Meter and wallbox via RS485; the data stick connects to the S-Miles Cloud for PC and smartphone.
    System diagram based on the Hoymiles template, labeled in German: DC side green, AC side red, communication dashed. Tap to enlarge.
    Hand holding a smartphone with the Hoymiles S-Miles app: house view with energy flows and daily valuesLaptop with the S-Miles Cloud web portal: power chart of a PV system
    S-Miles app and web portal, manufacturer view

    Monitoring

    S-Miles Cloud:
    the system at a glance

    The data stick connects the HIT to the Hoymiles S-Miles Cloud. You and your customer see energy flows and power curves in the app and in the web portal, and you can diagnose and service the system remotely.

    • App and web portalEnergy flow, daily values and power curve for operators and installers
    • Remote serviceRemote diagnostics and monitoring without a site visit
    • Setup via appCommissioning via QR code in four steps, about 5 minutes according to the manufacturer
    • ConnectionG3: WLAN, LAN (only with the DTS-WL-G3 stick) or 4G; G3S: WLAN, Ethernet or 4G

    References

    Hoymiles references:
    Vietnam and Thailand

    Two reference projects from the Hoymiles system brochure, both with HIT-20L-G3 and a battery of the G2 generation.

    Aerial view of a villa in Hanoi with a PV system on several roof areas, reference project with Hoymiles HIT-20L-G3
    Hanoi, Vietnam

    Villa with solar and battery

    HIT-20L-G3 with G2 battery LB-5D-G2, approx. 20 kWh. 12.93 MWh generation per year.

    over 1,400EURannual savings from tariff use
    8%additional yield according to the manufacturer
    Aerial view of the carport of a paint factory in Samut Prakan, Thailand: PV modules on the carport roof, company vehicles in charging spaces below
    Samut Prakan, Thailand

    PV carport, battery and charging at a paint factory

    HIT-20L-G3 with G2 battery LB-5D-G2, approx. 20 kWh. PV on the carport, with charging spaces for the company vehicles underneath. 11 MWh generation per year.

    980USDannual savings from tariff use
    8%additional yield according to the manufacturer

    Key figures according to Hoymiles (system brochure V20250104), not verified by PVSelected. The battery designation LB-5D-G2 stated there does not match the shop designation LB-5S-G2.

    Manufacturer

    Hoymiles:
    power electronics
    since 2012

    Hoymiles Power Electronics was founded in 2012, is publicly listed and is represented in Europe by its own company in Frankfurt am Main. The HIT Series is the manufacturer's three-phase hybrid solution for low-voltage batteries.

    2012founded
    Listedon the stock exchange, ticker 688032
    Frankfurthome of the EU company

    Technical data

    Series datasheet

    Common values of the five models in the shop. Where the classes differ, this is stated. Model-specific values are shown above in the model overview.

    All technical data of the series (6 tables)
    Battery connection
    Battery typeLi-ion or lead-acid
    Voltage range40 to 60 V
    Max. charge and discharge current150 A (6L) to 350 A (20L)
    BMS communicationCAN
    Charging strategyLi-ion according to BMS, lead-acid 3-stage with equalization charge
    External temperature sensoroptional, included with G3
    PV input
    Max. input voltage1,000 V
    Rated voltage720 V
    Start-up voltage150 V
    MPP voltage range150 to 900 V
    Current per MPPT20 A, short-circuit 30 A
    DC/AC oversizingup to 200 %
    AC on-grid
    Grid type3L/N/PE
    Rated voltage380/400 V, 266 to 480 V
    Frequency50/60 Hz
    Power factor> 0.99, adjustable from 0.8 inductive to 0.8 capacitive
    Current harmonics THDi< 3 %
    Backup power
    Rated powersame as on-grid
    Peak2 × rated power for 10 s
    Bypass continuous current50 A
    Switchover time10 ms max. according to the manufacturer's documents ¹
    Unbalanced load100 %, up to 50 % of the rated power per phase
    Voltage quality THDv< 3 % with linear load
    General
    Dimensions W × H × D539 × 696 × 232 mm
    Weight41 kg
    MountingWall mounting
    Operating temperature-25 to +65 °C, derated from 45 °C
    Humidity, altitude0 to 95 %, up to 4,000 m (derated from 2,000 m)
    Protection ratingIP66
    Cooling6L natural convection, from 8L controlled fan
    TopologyPV transformerless, battery high-frequency isolated
    DisplayG3S color display and app, G3 LED ring and app
    CommunicationRS485; G3 WLAN, LAN (data stick DTS-WL-G3) or 4G optional; G3S WLAN, Ethernet or 4G optional
    Digital inputs and outputsDRM, 2 × DI, 2 × DO
    Protection and standards according to datasheet
    Protective functionsAnti-islanding protection, PV reverse polarity protection, insulation and residual current monitoring, AC overcurrent, short-circuit and voltage protection; AFCI optional
    Surge protectionDC Type II, AC Type II
    Grid connection, all modelsVDE-AR-N 4105, EN 50549, IEC 61727, IEC 62116
    Additionally G3Sincl. TOR Erzeuger Typ A, G98, G99
    Safety and EMCIEC 62109-1/-2, EN 61000-6-1/-2/-3/-4
    WarrantyWarranty terms on request, extended warranty service EWS-5Y in the shop ²

    ¹ The manufacturer's documents state values between 0 and 10 ms, depending on the document; the G3S datasheet gives no clear value. For planning, 10 ms max. applies.

    ² We offer the extended warranty service EWS-5Y (5 additional years) in the shop for HIT-10L-G3 and HIT-15/20L-G3. Standards listed in the datasheet are not unit certificates; we compile the documentation for the grid operator on request.

    Batteries for the HIT Series
    BatteryEnergyContinuous currentPeak 10 sDimensionsWeightProtection ratingIn the shop
    LB-6D-G36.02 kWh60 A90 A514 × 236 × 410 mm ³55 kgIP65 ⁵yes
    LB-16D-G316.08 kWh160 A240 A824 × 236 × 410 mm ³115 kgIP65 ⁵yes
    LB-10D-G310.04 kWh100 A150 A664 × 236 × 410 mm ³80 kgIP65no, manufacturer value
    LB-5S-G2-Pack5.12 kWhn/a ⁴n/a ⁴640 × 690 × 145 mm60.5 kgIP66yes

    LB-G3 common data: LiFePO4, 314 Ah, 51.2 V (44.8 to 58.4 V), 8,000 cycles at 25 °C, 0.5 C, 90 % depth of discharge to 70 % remaining capacity, -20 to 55 °C with self-heating, indoors and outdoors, up to 16 modules in parallel. Old and new modules can only be mixed with LB-6D-G3 and LB-10D-G3; an integrated DC/DC converter balances them.

    ³ Order as in the manufacturer's table; the first value is the height. ⁴ The manufacturer's documents for this page do not state the rated voltage, cycles or charge and discharge current of the G2 packs; we will provide them on request. The G2 stack includes the base LB-(5-20)S-G2-Base (640 × 70 × 145 mm) and the PDU box LB-10C-G2 (640 × 240 × 145 mm, 11 kg); up to 4 packs per stack according to the type designation (calculated value, 5.12 to 20.48 kWh); G2 series -10 to 45 °C. ⁵ The manufacturer's leaflet 07/2026 states IP65 for LB-G3, the shop texts IP66; we state the more conservative value.

    Preview of the German Hoymiles HIT flyer by PVSelected, page 1
    Download

    HIT Series flyer (German)

    Two pages, designed together with Hoymiles: HIT-(5-20)L-G3 range, batteries and key values to pass on to your customers. PDF in German, 0.6 MB.

    Download flyer as PDF

    Mounting, connection and clearances

    What you really
    need on site

    Weight, clearances, cross-sections and sequence from the Quick Installation Guide. Use them to plan materials and the installation date before the van leaves.

    41kgInverter weight
    IP66Protection rating, outdoor wall mounting
    -25…65°COperation, derated from 45 °C
    539×696mmWidth × height, depth 232 mm
    Open connection compartment of the Hoymiles HIT inverter with spring terminals for wiring
    Connection compartment with spring terminals, connection panel on the underside
    Installation

    Clearances and mounting position

    Wall mounting only, vertical with a tilt of no more than 15° forward or backward. Drill hole Ø 10 mm, 80 mm deep, wall bracket with four expansion anchors (wrench size 13, 2.5 to 3 N·m); the unit is secured to the bracket with M5 (T25, 1.8 N·m).

    Top500 mm
    Bottom500 mm
    Left and right500 mm
    Front1,000 mm
    Between two units side by side500 mm

    Scope of delivery according to the Quick Installation Guide: inverter, wall bracket, Smart Meter with three current transformers, data stick, communication cable 5 m, battery temperature sensor, ferrite rings and mounting material.

    Cross-sections, connection sequence and commissioning
    Cables

    Cross-sections per connection

    PV per string2.5 to 4 mm²
    AC GRID, EPS, GEN2.5 to 4 mm² up to 15L, 4 to 6 mm² from 17L; 10 mm² for GRID and EPS when using the bypass
    Grounding2.5 to 4 mm² up to 15L, 4 to 6 mm² from 17L; 10 mm² when using the bypass
    Battery 6L50 to 70 mm²
    Battery 8L and 10L70 to 95 mm²
    Battery 15L120 to 150 mm²
    Battery 20L150 mm²
    Communication COM20.5 to 0.8 mm²

    Copper cables rated for 90 °C. Battery connection at 35 N·m, stripping length 30 mm. Route the battery cables as well as L1, L2, L3 and N of GRID and EPS once through the supplied ferrite ring and wrap them around it once. The Quick Installation Guide applies to the G3 models; there is no separate guide for the G3S variants, whose housing and dimensions are identical.

    Sequence

    Connecting and commissioning

    1. Grounding
    2. PV
    3. Battery
    4. AC: GRID, EPS and GEN
    5. Communication COM1 and COM2
    6. Close the cover of the connection compartment (M5, T25, 1.8 N·m)
    7. Plug in the data stick, WLAN or LAN mode (LAN only with DTS-WL-G3)

    Switching on

    1. Switch on the battery main switch and the battery DC disconnector
    2. Switch on the AC switch between inverter and grid
    3. Set the inverter DC switch to ON
    4. Check the status on the indicators: State, PV, AC, Meter, Battery

    Then set up the system with the Hoymiles app via the QR code: detect devices, configure functions, self-test, network. According to the manufacturer, this takes about 5 minutes.

    The Quick Installation Guide does not specify fuse ratings for AC and DC; it only requires a battery circuit breaker, a DC disconnector and an AC switch to the grid. We coordinate the values for your project as part of the system sizing. Wait at least 5 minutes before opening the unit; surfaces can get hotter than 60 °C. Installation by trained professionals only.

    It's that simple

    Three steps
    to your quote

    No paperwork, no long waiting times. From request to delivery from our Willich warehouse.

    1

    Submit a request

    PV power, desired capacity and quantity via the form. The sizing calculator above gives you the starting point.

    2

    Sizing and terms

    Your personal contact gets back to you within 24 hours with power class, battery, cable cross-sections and the price for your quantity.

    3

    Delivery from Willich

    Stock items usually reach you within 24 to 48 hours, at your warehouse or directly on site, together with the manufacturer's documents for registration with the grid operator.

    Your benefits

    9 reasons why installers trust PVSelected

    Everything you need to make your PV business more efficient, more profitable and more reliable.

    Exclusive B2B terms

    Attractive wholesale prices, volume discounts and transparent availability, directly in your personal B2B shop.

    Technical support in three stages

    From the initial consultation through system configuration to commissioning: our technical team is at your side.

    Free training

    Practical training in the PVSelected Academy: product knowledge, installation, sales and commissioning.

    Personal contact

    No call center, no ticket system. One dedicated contact person who knows your projects and requirements.

    B2B shop with real-time data

    Your own online access with real-time stock levels, individual prices, order history and easy reordering.

    Reliable supply chains

    Stable supply chain with our own warehouse capacity. Fast delivery directly to the job site or to your warehouse.

    Project planning and sizing

    Support with system planning, battery sizing and system configuration for optimal results.

    Documents for the grid operator

    We compile datasheets, installation instructions and manufacturer information on grid compliance for your registration. We request anything missing from Hoymiles.

    No end-customer business

    We supply installers and trade partners exclusively, so we never compete with you for your own orders.

    500+active installer partners
    24–48hdelivery time for stock items
    DACH+NLdelivery area
    Willichwarehouse and shipping

    Frequently asked questions

    What installers
    ask about the HIT

    Answers from datasheets, the Quick Installation Guide and manufacturer documents. Your question is not listed? Call us at +49 2154 5029131 or submit a request.

    How much power does the HIT deliver in backup mode?

    Up to the rated power of the respective class, i.e. 6, 8, 10, 15 or 20 kW, provided PV and battery can deliver this power. Without PV, the battery current is the limit: an LB-6D-G3 delivers 60 A continuously, calculated at approx. 3.1 kW at 51.2 V. For 10 seconds, the HIT provides twice its rated power, 40,000 VA with the HIT-20L-G3, again only with sufficient PV and battery power. In on-grid mode, the bypass carries up to 50 A to the backup loads. In backup mode, 100 % unbalanced load is permitted, up to 50 % of the rated power per phase.

    Which model suits which PV power?

    The decisive factor is the recommended maximum PV power according to the datasheet: 12 kW for the HIT-6L-G3S, 16 kW for the HIT-8L-G3S, 20 kW for the HIT-10L-G3, 30 kW for the HIT-15L-G3 and 40 kW for the HIT-20L-G3. This corresponds to oversizing of 200 %. Each MPP tracker accepts up to 20 A; the smaller classes have 2 and 3 trackers, HIT-15L-G3 and HIT-20L-G3 have 4 each. For the HIT-10L-G3 we plan for 3 trackers; the G3 V1.0 datasheet states 4, and we are clarifying this with Hoymiles.

    Which battery fits, and how far can it be expanded?

    In the shop we offer the LB-6D-G3 with 6.02 kWh and 60 A continuous current, the LB-16D-G3 with 16.08 kWh and 160 A, and the stackable battery LB-5S-G2 with 5.12 kWh per pack. The LB-G3 batteries are individual units for wall, floor or wheeled installation and are connected electrically in parallel, up to 16 units; the calculated capacity is 96.32 kWh with LB-6D-G3 and 257.28 kWh with LB-16D-G3. According to the manufacturer, the G2 range covers 5.12 to 102.4 kWh, with up to 4 packs per stack (calculated value from the type designation LB-(5-20)S-G2). The choice depends on capacity, the required battery current and the weight at the installation site: 55 kg for the LB-6D-G3, 115 kg for the LB-16D-G3.

    Can I combine old and new battery modules?

    For LB-6D-G3 and LB-10D-G3, Hoymiles allows mixing old and new modules; an integrated DC/DC converter balances the states of charge. According to the manufacturer, this function does not apply to the LB-16D-G3. Hoymiles does not describe combining G2 and G3 batteries, so please check this with us in advance.

    How quickly does the HIT switch to backup power?

    The manufacturer's documents state values between 0 and 10 ms, depending on the document. Please plan for 10 ms max.; if required, we will agree a binding value for your project with Hoymiles.

    Can the HIT be installed outdoors?

    Yes. The inverter is rated IP66 and operates from -25 to +65 °C, with derating from 45 °C. The Quick Installation Guide permits outdoor wall mounting exposed to sun, rain and snow. Clearances of 500 mm to the top, bottom and sides and 1,000 mm to the front must be maintained. The LB-G3 batteries are rated IP65 and heat themselves in cold conditions, operating range -20 to 55 °C.

    Which batteries can I connect?

    The datasheet lists lithium-ion and lead-acid batteries in the voltage range from 40 to 60 V. Lithium batteries communicate with the inverter via CAN, and charging follows the BMS; lead-acid batteries are charged in three stages with an equalization charge. For new systems, we recommend the Hoymiles batteries from the shop, because monitoring and your point of contact then come from a single source.

    What is the GEN port for?

    A generator can be connected to the GEN port as a fourth energy source alongside PV, battery and grid. Alternatively, the port supplies loads and controls their power consumption. Via the COM2 interface, the HIT also controls heat pumps via analog signal or SG Ready and can control a generator.

    How do I monitor the system?

    Via the Hoymiles S-Miles Cloud, as an app and in the web portal: energy flows, power curve, remote diagnostics. The connection is established by the data stick: with G3 via WLAN, LAN (only with the DTS-WL-G3 stick) or 4G, with G3S via WLAN, Ethernet or 4G. Commissioning is done in the Hoymiles app via QR code.

    What is the difference between G3 and G3S?

    The G3S models have a color display, the G3 models an LED ring. The G3S datasheet lists more grid connection standards, including TOR Erzeuger Typ A for Austria. Within the same power class, the electrical characteristics are largely identical; the exceptions are the number of MPPTs in the 10 kW class and the switchover time specification. In the shop, the 6 and 8 kW classes are G3S, the 10, 15 and 20 kW classes G3.

    Which standards does the HIT meet?

    The datasheets of all five shop models list VDE-AR-N 4105 and EN 50549, plus IEC 62109 for safety. TOR Erzeuger Typ A is only listed in the datasheet of the G3S models. A datasheet listing does not replace a unit certificate: we compile the documentation for the grid operator for your registration and request anything missing from Hoymiles.

    Technical assessment

    Where the HIT is
    the right approach

    Where the range has its strengths, where it reaches its limits and what this means for system sizing.

    Low voltage instead of high voltage

    The HIT works with batteries between 40 and 60 V; the LB-G3 batteries have a rated voltage of 51.2 V. This means the modules can be placed individually and expanded in parallel, up to 16 units. The trade-off is high currents: up to 350 A on the HIT-20L-G3, battery cables up to 150 mm². So plan cable routes and cross-sections before installation. Other Hoymiles solutions: the HiOne and the HiBattery.

    When the range pays off

    The five shop models cover 6 to 20 kW, from single-family homes to small businesses. Oversizing of up to 200 % and up to four MPP trackers help with east-west roofs and multiple roof areas. The range is at its strongest where backup power for the entire house distribution board is needed or a generator is to be integrated, for example on farms.

    Limits you should know

    The inverter is approved for wall mounting only; floor and wheeled installation refer to the batteries. The battery current is often limited by the battery: an LB-6D-G3 delivers 60 A continuously, the HIT-20L-G3 could handle 350 A. This also applies to the backup peak without PV. Battery cables need up to 150 mm², and we define the fusing together with you. TOR Erzeuger Typ A is only listed in the datasheet of the G3S models.

    What PVSelected contributes

    We clarify power class, battery, cross-sections and fusing before you order, obtain missing manufacturer information from Hoymiles and have the documents for the grid operator ready. Requests are handled via our request form, and ready-made packages can be ordered directly in the B2B shop.

    SourcesHoymiles datasheet HIT-(5-20)L-G3 REV1.0 (© 2024) · Datasheet HIT-(5-20)L-G3S REV1.2 (© 2026) · Quick Installation Guide HIT-(5-20)L-G3 REV1.2 (© 2025) · HIT Tri-fold Leaflet (07/2026) · HIT Series A4 flyer DE (PVSelected) · Three-phase Low-voltage System Solution V20250104 · B2B shop b2b.pvselected.de, as of 25.09.2026. All information is provided without guarantee; the current manufacturer documents are authoritative. More basics in our PV knowledge section (in German).